V38.03
3 fittings and 2 check valve inserts
- Acceptable working temperature range (peaks): -20 (see suitable fluids)–110 °C
- Working temperature range: 0 (no frost)–110 °C
- Check valve opening pressure: 0,05 bar
- Max working pressure: 16 bar
- Suitable fluids: water for thermal systems, glycol solutions (max 50%), domestic water
- Threaded connections: ISO 228-1